Jiangsu Acrel Electrical Manufacturing CO.,LTD

Tel:+86-18761593924

E-Mail:lukas.lu@email.acrel.cn

APM800 Multi-function Power Network Analyzer

APM800 Multi-function Power Network Analyzer

APM series meters have full power measurement, energy statistics, analysis of power quality and network communications and other functions.

description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
Description
Major Characteristics
  • Three-phase,U,I,kW, kWh, kVarh,  Hz, Cosφ
  • Four quadrant electrical energy
  • Real-time and maximum demand
  • Current voltage unbalance degree
  • Load current histogram display
  • A total of 66 kinds of alarm types, each type can record the most recent 16 alarm records, support extended records by TF card
  • 2DI+2DO
  • LCD display
  • Accuracy of Active power: 0.5s
  • RS485/Modbus
Panel Features
 
 
 

 

Wiring

 

Installation
 
 
Network Structure

 

Installation On-Site

 

 

  •  
Package

 

MINIMUM PACKAGE

 

 

MINIMUM PACKAGE

 

Package Dimension(1 PC)

170*150*130mm

Package Weight(1 PC)

0.372Kg

 

WHOLE BOX PACKAGE

 

Package Dimension(36 PCS)

540*530*480mm

Package Weight(36 PCS)

14.5kG

 

PRODUCT HS CODE

 

9028301400

 

Related Products
  • AKH-0.66/K-Φ Split Core Current Transformer For Cable
  • AMC72L-E4/KC Three-phase AC Multi-function Panel Energy Meter
  • AMC96L-E4/KC Three Phase AC Multi-function Panel Energy Meter
  • Acrel APM830 Three Phase Multi-function Panel Power Meter /Energy Analyzer
  •  
  •  
  •  
  •  
Data Sheet
Product Functions

Function

Function description

APM800
(class 0.5s)

APM801
(class 0.2s)

APM810
(class 0.5s)

APM830
(class 0.2s)

Parameters

All parameters

Four-quadrant energy

Multi-rate energy

Pulse output of energy

Active/reactive

Demand

Real-time and maximum demand of I, P, Q,S (with time)

Extreme value statistics

Extremum of I, UL-L, UL-N, P, Q, S, PF, F, THDi, THDu in this month and last month (with time)

 ■

 ■

 ■

 ■

Power quality

Unbalance of I,UL-L,UL-N

Voltage phase angle,current phase angle

Total and 2nd-63rd harmonic content of voltage and current

-

-

Voltage crest factor

-

-

Telephone waveform factor

-

-

Current K-factor

-

-

Positive sequence, negative sequence, zero sequence voltage and current

-

-

-

Fundamental voltage and current

-

-

-

Waveform

Waveform trace display

-

-

-

Fault waveform record

-

-

-

Alarm

A total of 66 kinds of alarm types, each type can record the most recent 16 alarm records,support extended records by TF card

 ■

 ■

 ■

 ■

Event

Record the most recent 128 event records, support extended records by TF card

 ■

 ■

 ■

 ■

Communication

RS485(Modbus-RTU)

I/O

2DI+2DO

 

Optional functions

MD82

8DI+2DO

MLOG

TF card

MA84

8AI+4AO

MCM

1 RS485(Modbus-RTU),support master mode or slave mode

 ■

 ■

 ■

 ■

MCMP

1 Profibus(Profibus-DP)

MCME

1 Ethernet(Modbus-TCP,HTTP,DHCP)

 

Note:① Accuracy of 2-42nd harmonic measurement in the frequency range of 45~65Hz is 1%, accuracy of 43-63rd harmonic measurement in frequency range of 50Hz is 2%.

          ② “■”:standard “-”:No “□”:Optional

 

Technical Parameter

Technical Parameter

Value

Signal

Connection

3 phase 3 wire, 3 phase 4 wire

Frequency

45~65Hz

Voltage

Rated value: AC 100V,110V,400V,690V

Overload: 1.2 times rated value(continuous); 2 times rated value(1 second)

Power consumption: < 0.5VA (per channel)

Current

Rated value: AC 1A, 5A

Overload: 1.2 times rated value(continuous); 10 times rated value(1 second)

Power consumption: < 0.5VA (per channel)

Measurement accuracy

Voltage,current and power

Class 0.5S (APM800,APM810)

Class 0.2S (APM801,APM830)

Active power

Reactive power

Class 2(APM800, APM810), Class 0.5(APM801,830)

Harmonic

1%(2~42nd),2%(43~63rd)

Switch inputs

Passive contact inputs, built-in power supply

Relay outputs

Contact type: open contact in main part, changeover contact in module Contact capacity:3A/AC 250V 3A/DC 30V

 

Pulse output of energy

 

Output mode: Optocoupler pulse with open collector Pulse constant:4000(5A),8000(1A) imp/kWh

Analog outputs

DC 0~20mA,4~20mA,0~5V,1~5V output, accuracy class 0.5%, load resistance ≤ 500Ω

Analog inputs

DC 0~20mA,4~20mA,0~5V,1~5V input, accuracy class 0.5%

Storage card

Standard capacity:4G,TF card up to 32G capacity

Communication

RS485(Modbus-RTU)

Profibus(Profibus-DP)

Ethernet(Modbus-TCP,HTTP,DHCP)

 

Auxiliary power supply

Operating range: AC/DC 85V~265V or AC/DC 115~415V(P2)

Power consumption: Power consumption of the main part ≤ 15VA

Safety

Insulation resistance

>100MΩ

Electromagnetic compatibility

IEC 61000 standard (Level 4)

Protection level

IP54(Front)

 

 

Technical Parameter

Value

Environment

Operating temperature: -20 °C ~ +65 °C

Storage temperature: -20°C~+70°C

Relative humidity: ≤95%(no condensation)

Altitude: ≤2500m

CONTACT US