DTSD1352 three phase din rail electric meter is a smart meter designed for power supply system,industrial and mining enterprises and utilities to calculate the electricity consumption and manage the electric demand. It features the high precision, small size and simple installation.
MINIMUM PACKAGE
|
||||
MINIMUM PACKAGE
|
Package Dimension(1 PC) 170*150*130mm |
Package Weight(1 PC) 0.372Kg |
||
WHOLE BOX PACKAGE
|
Package Dimension(36 PCS) 540*530*480mm |
Package Weight(36 PCS) 14.5kG |
||
PRODUCT HS CODE
|
9028301400 |
Function |
Function description |
Function provide |
Measurement of kWh |
Active kWh (positive and negative) |
■ |
Reactive kWh (positive and negative) |
■ |
|
A, B, C phase positive active kWh |
■ |
|
Measurement of electrical parameters |
U、I、P、Q、S、PF、F |
■ |
Measurement of |
2~31ST Voltage and current harmonic |
□ |
LCD Display |
8 bits section LCD display, background light |
■ |
Key programming |
4 keys to communication and set parameters |
■ |
Pulse output |
Active pulse output |
■ |
Reactive pulse output |
□ |
|
Clock pulse output |
□ |
|
Multi-tariff and functions |
Active switch input |
□ |
Switch output |
□ |
|
Adapt 4 time zones, 2 time interval lists, 14 time interval by day and 4 tariff rates |
□ |
|
Max demanded kWh and time happened |
□ |
|
Frozen data on last 48 months, last 90days |
□ |
|
Date, time |
□ |
|
Communication |
Infrared communication |
■ |
The first communication path: Communication interface: RS485, Communication protocol: MODBUS-RTU |
□ |
|
The second communication path: Communication interface: RS485, Communication protocol: MODBUS-RTU |
□ |
|
Temperature measurement |
Support 3 outlay NTC temperature |
□ |
“■” means standard, “□” means optional.
Specification |
3 phase 3 wires, 3 phase 4 wires |
|
Voltage |
Reference voltage |
3×100V、 3×380V、3×57.7/100V、 3×220/380V |
Consumption |
<10VA(Single phase) |
|
Impedance |
>2MΩ |
|
Accuracy class |
Error±0.2% |
|
Current |
Input current |
3×1(6)A (second connection with CTs’ cable already on site via external CTs of ADL3000-E/CT) 3×10(100)A (first connection with 3-phase load line via external CTs of ADL3000-E/CT)
|
Consumption |
<1VA(Single phase rated current) |
|
Accuracy class |
Error±0.2% |
|
Power |
Active, reactive, apparent power, error±0.5℅ |
|
Frequency |
45~65Hz, Error±0.2% |
|
Temperature |
-40℃~99℃ |
|
Energy |
Active energy (Accuracy class:0.5, 1), reactive energy(Accuracy class 2) |
|
Clock |
≤0.5s/d |
|
Energy pulse output |
1 active optocoupler output, 1 reactive optocoupler output |
|
Switching output |
1 Switching output |
|
Switching input |
1 optocoupler input |
|
Width of pulse |
80±20ms |
|
Pulse constant |
6400imp/kWh,400imp/kWh(Correspond with the basic current) |
|
Interface and communication |
RS485:Modbus RTU |
|
Range of communication address |
Modbus RTU:1~ 247; |
|
Baud rate |
1200bps~19200bps |
|
Relative temperature |
-25℃~+55℃ |
|
Relative humidity |
≤95℅(No condensation) |